196 research outputs found

    Multimodality Biomedical Image Registration Using Free Point Transformer Networks

    Get PDF
    We describe a point-set registration algorithm based on a novel free point transformer (FPT) network, designed for points extracted from multimodal biomedical images for registration tasks, such as those frequently encountered in ultrasound-guided interventional procedures. FPT is constructed with a global feature extractor which accepts unordered source and target point-sets of variable size. The extracted features are conditioned by a shared multilayer perceptron point transformer module to predict a displacement vector for each source point, transforming it into the target space. The point transformer module assumes no vicinity or smoothness in predicting spatial transformation and, together with the global feature extractor, is trained in a data-driven fashion with an unsupervised loss function. In a multimodal registration task using prostate MR and sparsely acquired ultrasound images, FPT yields comparable or improved results over other rigid and non-rigid registration methods. This demonstrates the versatility of FPT to learn registration directly from real, clinical training data and to generalize to a challenging task, such as the interventional application presented

    Real-time multimodal image registration with partial intraoperative point-set data

    Get PDF
    We present Free Point Transformer (FPT) - a deep neural network architecture for non-rigid point-set registration. Consisting of two modules, a global feature extraction module and a point transformation module, FPT does not assume explicit constraints based on point vicinity, thereby overcoming a common requirement of previous learning-based point-set registration methods. FPT is designed to accept unordered and unstructured point-sets with a variable number of points and uses a "model-free" approach without heuristic constraints. Training FPT is flexible and involves minimizing an intuitive unsupervised loss function, but supervised, semi-supervised, and partially- or weakly-supervised training are also supported. This flexibility makes FPT amenable to multimodal image registration problems where the ground-truth deformations are difficult or impossible to measure. In this paper, we demonstrate the application of FPT to non-rigid registration of prostate magnetic resonance (MR) imaging and sparsely-sampled transrectal ultrasound (TRUS) images. The registration errors were 4.71 mm and 4.81 mm for complete TRUS imaging and sparsely-sampled TRUS imaging, respectively. The results indicate superior accuracy to the alternative rigid and non-rigid registration algorithms tested and substantially lower computation time. The rapid inference possible with FPT makes it particularly suitable for applications where real-time registration is beneficial

    Designing image segmentation studies: Statistical power, sample size and reference standard quality.

    Get PDF
    Segmentation algorithms are typically evaluated by comparison to an accepted reference standard. The cost of generating accurate reference standards for medical image segmentation can be substantial. Since the study cost and the likelihood of detecting a clinically meaningful difference in accuracy both depend on the size and on the quality of the study reference standard, balancing these trade-offs supports the efficient use of research resources. In this work, we derive a statistical power calculation that enables researchers to estimate the appropriate sample size to detect clinically meaningful differences in segmentation accuracy (i.e. the proportion of voxels matching the reference standard) between two algorithms. Furthermore, we derive a formula to relate reference standard errors to their effect on the sample sizes of studies using lower-quality (but potentially more affordable and practically available) reference standards. The accuracy of the derived sample size formula was estimated through Monte Carlo simulation, demonstrating, with 95% confidence, a predicted statistical power within 4% of simulated values across a range of model parameters. This corresponds to sample size errors of less than 4 subjects and errors in the detectable accuracy difference less than 0.6%. The applicability of the formula to real-world data was assessed using bootstrap resampling simulations for pairs of algorithms from the PROMISE12 prostate MR segmentation challenge data set. The model predicted the simulated power for the majority of algorithm pairs within 4% for simulated experiments using a high-quality reference standard and within 6% for simulated experiments using a low-quality reference standard. A case study, also based on the PROMISE12 data, illustrates using the formulae to evaluate whether to use a lower-quality reference standard in a prostate segmentation study

    Prostate Motion Modelling Using Biomechanically-Trained Deep Neural Networks on Unstructured Nodes

    Get PDF
    In this paper, we propose to train deep neural networks with biomechanical simulations, to predict the prostate motion encountered during ultrasound-guided interventions. In this application, unstructured points are sampled from segmented pre-operative MR images to represent the anatomical regions of interest. The point sets are then assigned with point-specific material properties and displacement loads, forming the un-ordered input feature vectors. An adapted PointNet can be trained to predict the nodal displacements, using finite element (FE) simulations as ground-truth data. Furthermore, a versatile bootstrap aggregating mechanism is validated to accommodate the variable number of feature vectors due to different patient geometries, comprised of a training-time bootstrap sampling and a model averaging inference. This results in a fast and accurate approximation to the FE solutions without requiring subject-specific solid meshing. Based on 160,000 nonlinear FE simulations on clinical imaging data from 320 patients, we demonstrate that the trained networks generalise to unstructured point sets sampled directly from holdout patient segmentation, yielding a near real-time inference and an expected error of 0.017 mm in predicted nodal displacement

    Assisted Probe Positioning for Ultrasound Guided Radiotherapy Using Image Sequence Classification

    Get PDF
    Effective transperineal ultrasound image guidance in prostate external beam radiotherapy requires consistent alignment between probe and prostate at each session during patient set-up. Probe placement and ultrasound image interpretation are manual tasks contingent upon operator skill, leading to interoperator uncertainties that degrade radiotherapy precision. We demonstrate a method for ensuring accurate probe placement through joint classification of images and probe position data. Using a multi-input multi-task algorithm, spatial coordinate data from an optically tracked ultrasound probe is combined with an image classifier using a recurrent neural network to generate two sets of predictions in real-time. The first set identifies relevant prostate anatomy visible in the field of view using the classes: outside prostate, prostate periphery, prostate centre. The second set recommends a probe angular adjustment to achieve alignment between the probe and prostate centre with the classes: move left, move right, stop. The algorithm was trained and tested on 9,743 clinical images from 61 treatment sessions across 32 patients. We evaluated classification accuracy against class labels derived from three experienced observers at 2/3 and 3/3 agreement thresholds. For images with unanimous consensus between observers, anatomical classification accuracy was 97.2% and probe adjustment accuracy was 94.9%. The algorithm identified optimal probe alignment within a mean (standard deviation) range of 3.7° (1.2°) from angle labels with full observer consensus, comparable to the 2.8° (2.6°) mean interobserver range. We propose such an algorithm could assist radiotherapy practitioners with limited experience of ultrasound image interpretation by providing effective real-time feedback during patient set-up

    Controlling False Positive/Negative Rates for Deep-Learning-Based Prostate Cancer Detection on Multiparametric MR images

    Get PDF
    Prostate cancer (PCa) is one of the leading causes of death for men worldwide. Multi-parametric magnetic resonance (mpMR) imaging has emerged as a non-invasive diagnostic tool for detecting and localising prostate tumours by specialised radiologists. These radiological examinations, for example, for differentiating malignant lesions from benign prostatic hyperplasia in transition zones and for defining the boundaries of clinically significant cancer, remain challenging and highly skill-and-experience-dependent. We first investigate experimental results in developing object detection neural networks that are trained to predict the radiological assessment, using these high-variance labels. We further argue that such a computer-assisted diagnosis (CAD) system needs to have the ability to control the false-positive rate (FPR) or false-negative rate (FNR), in order to be usefully deployed in a clinical workflow, informing clinical decisions without further human intervention. However, training detection networks typically requires a multi-tasking loss, which is not trivial to be adapted for a direct control of FPR/FNR. This work in turn proposes a novel PCa detection network that incorporates a lesion-level cost-sensitive loss and an additional slice-level loss based on a lesion-to-slice mapping function, to manage the lesion- and slice-level costs, respectively. Our experiments based on 290 clinical patients concludes that 1) The lesion-level FNR was effectively reduced from 0.19 to 0.10 and the lesion-level FPR was reduced from 1.03 to 0.66 by changing the lesion-level cost; 2) The slice-level FNR was reduced from 0.19 to 0.00 by taking into account the slice-level cost; (3) Both lesion-level and slice-level FNRs were reduced with lower FP/FPR by changing the lesion-level or slice-level costs, compared with post-training threshold adjustment using networks without the proposed cost-aware training. For the PCa application of interest, the proposed CAD system is capable of substantially reducing FNR with a relatively preserved FPR, therefore is considered suitable for PCa screening applications

    Automatic segmentation of prostate MRI using convolutional neural networks: Investigating the impact of network architecture on the accuracy of volume measurement and MRI-ultrasound registration

    Get PDF
    Convolutional neural networks (CNNs) have recently led to significant advances in automatic segmentations of anatomical structures in medical images, and a wide variety of network architectures are now available to the research community. For applications such as segmentation of the prostate in magnetic resonance images (MRI), the results of the PROMISE12 online algorithm evaluation platform have demonstrated differences between the best-performing segmentation algorithms in terms of numerical accuracy using standard metrics such as the Dice score and boundary distance. These small differences in the segmented regions/boundaries outputted by different algorithms may potentially have an unsubstantial impact on the results of downstream image analysis tasks, such as estimating organ volume and multimodal image registration, which inform clinical decisions. This impact has not been previously investigated. In this work, we quantified the accuracy of six different CNNs in segmenting the prostate in 3D patient T2-weighted MRI scans and compared the accuracy of organ volume estimation and MRI-ultrasound (US) registration errors using the prostate segmentations produced by different networks. Networks were trained and tested using a set of 232 patient MRIs with labels provided by experienced clinicians. A statistically significant difference was found among the Dice scores and boundary distances produced by these networks in a non-parametric analysis of variance (p < 0.001 and p < 0.001, respectively), where the following multiple comparison tests revealed that the statistically significant difference in segmentation errors were caused by at least one tested network. Gland volume errors (GVEs) and target registration errors (TREs) were then estimated using the CNN-generated segmentations. Interestingly, there was no statistical difference found in either GVEs or TREs among different networks, (p = 0.34 and p = 0.26, respectively). This result provides a real-world example that these networks with different segmentation performances may potentially provide indistinguishably adequate registration accuracies to assist prostate cancer imaging applications. We conclude by recommending that the differences in the accuracy of downstream image analysis tasks that make use of data output by automatic segmentation methods, such as CNNs, within a clinical pipeline should be taken into account when selecting between different network architectures, in addition to reporting the segmentation accuracy

    Assessment of Electromagnetic Tracking Accuracy for Endoscopic Ultrasound

    Get PDF
    Endoscopic ultrasound (EUS) is a minimally-invasive imaging technique that can be technically difficult to perform due to the small field of view and uncertainty in the endoscope position. Electromagnetic (EM) tracking is emerging as an important technology in guiding endoscopic interventions and for training in endotherapy by providing information on endoscope location by fusion with pre-operative images. However, the accuracy of EM tracking could be compromised by the endoscopic ultrasound transducer. In this work, we quantify the precision and accuracy of EM tracking sensors inserted into the working channel of a flexible endoscope, with the ultrasound transducer turned on and off. The EUS device was found to have little (no significant) effect on static tracking accuracy although jitter increased significantly. A significant change in the measured distance between sensors arranged in a fixed geometry was found during a dynamic acquisition. In conclusion, EM tracking accuracy was not found to be significantly affected by the flexible endoscope

    Towards image-guided pancreas and biliary endoscopy: Automatic multi-organ segmentation on abdominal CT with dense dilated networks

    Get PDF
    Segmentation of anatomy on abdominal CT enables patient-specific image guidance in clinical endoscopic procedures and in endoscopy training. Because robust interpatient registration of abdominal images is necessary for existing multi-atlas- and statistical-shape-model-based segmentations, but remains challenging, there is a need for automated multi-organ segmentation that does not rely on registration. We present a deep-learning-based algorithm for segmenting the liver, pancreas, stomach, and esophagus using dilated convolution units with dense skip connections and a new spatial prior. The algorithm was evaluated with an 8-fold cross-validation and compared to a joint-label-fusion-based segmentation based on Dice scores and boundary distances. The proposed algorithm yielded more accurate segmentations than the joint-label-fusion-ba sed algorithm for the pancreas (median Dice scores 66 vs 37), stomach (83 vs 72) and esophagus (73 vs 54) and marginally less accurate segmentation for the liver (92 vs 93). We conclude that dilated convolutional networks with dense skip connections can segment the liver, pancreas, stomach and esophagus from abdominal CT without image registration and have the potential to support image-guided navigation in gastrointestinal endoscopy procedures

    Automatic Multi-organ Segmentation on Abdominal CT with Dense V-networks

    Get PDF
    Automatic segmentation of abdominal anatomy on computed tomography (CT) images can support diagnosis, treatment planning and treatment delivery workflows. Segmentation methods using statistical models and multi-atlas label fusion (MALF) require inter-subject image registrations which are challenging for abdominal images, but alternative methods without registration have not yet achieved higher accuracy for most abdominal organs. We present a registration-free deeplearning- based segmentation algorithm for eight organs that are relevant for navigation in endoscopic pancreatic and biliary procedures, including the pancreas, the GI tract (esophagus, stomach, duodenum) and surrounding organs (liver, spleen, left kidney, gallbladder). We directly compared the segmentation accuracy of the proposed method to existing deep learning and MALF methods in a cross-validation on a multi-centre data set with 90 subjects. The proposed method yielded significantly higher Dice scores for all organs and lower mean absolute distances for most organs, including Dice scores of 0.78 vs. 0.71, 0.74 and 0.74 for the pancreas, 0.90 vs 0.85, 0.87 and 0.83 for the stomach and 0.76 vs 0.68, 0.69 and 0.66 for the esophagus. We conclude that deep-learning-based segmentation represents a registration-free method for multi-organ abdominal CT segmentation whose accuracy can surpass current methods, potentially supporting image-guided navigation in gastrointestinal endoscopy procedures
    • …
    corecore